"""River 3 tests using synthetic protobuf messages, not device captures.
Field numbers/types follow ha-ef-ble's proto/pr705.proto DisplayPropertyUpload.
The packet fixtures model the XOR framing used by upstream River 3 tests.
"""
import asyncio
import importlib.util
import struct
from dataclasses import asdict
from pathlib import Path
from unittest.mock import AsyncMock
import pytest
from bmspy.classes import UPS
from bmspy.ecoflow_bt import (
EcoFlowBTDevice, EcoFlowPacket, _EncFrameHelper, _State, _Type7Encryption,
)
from bmspy.ecoflow_river3 import decode_river3_payload
ADDRESS = "02:00:00:00:00:03"
SERIAL = "R651TEST00000001"
def varint(value):
value &= (1 << 64) - 1
data = bytearray()
while value > 127:
data.append((value & 127) | 128)
value >>= 7
data.append(value)
return bytes(data)
def integer(field, value):
return varint(field << 3) + varint(value)
def floating(field, value):
return varint((field << 3) | 5) + struct.pack("<f", value)
def report(payload):
return EcoFlowPacket(2, 0x21, 0xFE, 0x15, payload, version=3)
def device(serial=SERIAL):
return EcoFlowBTDevice(ADDRESS, serial, "test-user")
def display_payload(power=166):
return b"".join([
floating(262, 88.918), floating(3, 244), floating(4, 39),
floating(158, power), integer(259, 29), integer(269, 10),
integer(268, 184), integer(282, 1),
])
def test_decode_numeric_display_fields():
values = decode_river3_payload(2, 0xFE, 0x15, display_payload())
assert values["cms_batt_soc"] == pytest.approx(88.918)
assert values["pow_in_sum_w"] == 244
assert values["pow_out_sum_w"] == 39
assert values["pow_get_bms"] == 166
assert values["bms_max_cell_temp"] == 29
assert values["cms_chg_rem_time"] == 10
assert values["cms_dsg_rem_time"] == 184
assert values["cms_chg_dsg_state"] == 1
assert decode_river3_payload(2, 0xFE, 0x15, b"") == {}
@pytest.mark.parametrize("src,cmd_set,cmd_id", [(3, 0xFE, 0x15), (2, 0x20, 2), (2, 0xFE, 0x16)])
def test_unconfirmed_and_unrelated_messages_are_not_mapped(src, cmd_set, cmd_id):
assert decode_river3_payload(src, cmd_set, cmd_id, display_payload()) is None
@pytest.mark.parametrize("payload", [
b"\x00", b"\x80", b"\x80" * 11, b"\x08" + b"\xff" * 10,
varint(3 << 3 | 5) + b"\x00" * 3,
varint(99 << 3 | 1) + b"\x00" * 7,
varint(99 << 3 | 2) + varint(4) + b"abc",
varint(99 << 3 | 3), varint(1 << 32),
])
def test_malformed_protobuf_is_rejected_atomically(payload):
assert decode_river3_payload(2, 0xFE, 0x15, floating(3, 10) + payload) is None
def test_unknown_fields_and_wrong_wire_types_do_not_become_measurements():
payload = (
integer(3, 99) # Total input must be a float, not a varint.
+ integer(999, 123)
+ varint(998 << 3 | 1) + bytes(8)
+ varint(997 << 3 | 2) + varint(3) + b"abc"
+ floating(4, 10) + floating(4, 20)
)
assert decode_river3_payload(2, 0xFE, 0x15, payload) == {"pow_out_sum_w": 20}
def test_signed_temperatures_and_unsigned_time_validation():
payload = integer(102, -5) + integer(259, -3) + integer(269, 1 << 32)
assert decode_river3_payload(2, 0xFE, 0x15, payload) == {
"cms_batt_temp": -5, "bms_max_cell_temp": -3,
}
@pytest.mark.parametrize("prefix", ["R651", "R653", "R654", "R655"])
def test_river3_snapshot_and_serialization(prefix):
dev = device(prefix + "TEST00000001")
dev._record(report(display_payload()))
snap = dev.snapshot
assert dev._pkt_version == 3
assert snap.bms_capacity_charge_ratio.raw_value == pytest.approx(0.88918)
assert snap.bms_temperature_celsius.raw_values == {1: 29}
assert snap.ef_input_power_watts.raw_value == 244
assert snap.ef_output_power_watts.raw_value == 39
assert snap.bms_charge_is_charging.raw_value is True
assert snap.bms_charge_is_discharging.raw_value is False
assert snap.ef_remaining_time_minutes.raw_value == 10
assert snap.ef_charge_remaining_time_minutes.units == "min"
assert snap.ef_charge_state.raw_value == 1
serialized = {name: asdict(value) for name, value in snap.items()}
assert dict(UPS.from_dict(serialized).items()) == dict(snap.items())
@pytest.mark.parametrize("serial", ["R601TEST00000001", "R631TEST00000001", "unknown"])
def test_other_models_do_not_use_river3_decoder(serial):
dev = device(serial)
dev._record(report(display_payload()))
assert dev.snapshot.bms_capacity_charge_ratio is None
assert dev.snapshot.ef_input_power_watts is None
def test_partial_updates_keep_missing_values_and_preserve_explicit_zero():
dev = device()
dev._record(report(floating(262, 0)))
assert dev.snapshot.bms_capacity_charge_ratio.raw_value == 0
assert dev.snapshot.ef_input_power_watts is None
dev._record(report(floating(3, 44) + floating(4, 44)))
assert dev.snapshot.bms_charge_is_charging is None # AC bypass is not charging.
dev._record(report(floating(158, 0) + integer(102, -5)))
assert dev.snapshot.bms_charge_is_charging.raw_value is False
assert dev.snapshot.bms_charge_is_discharging.raw_value is False
assert dev.snapshot.ef_remaining_time_minutes is None
assert dev.snapshot.bms_temperature_celsius.raw_values == {1: -5}
assert dev.snapshot.ef_output_power_watts.raw_value == 44
def test_cell_temperature_remains_preferred_across_partial_updates():
dev = device()
dev._record(report(integer(259, 29)))
dev._record(report(integer(102, 26)))
assert dev.snapshot.bms_temperature_celsius.raw_values == {1: 29}
dev._record(report(integer(259, 30)))
assert dev.snapshot.bms_temperature_celsius.raw_values == {1: 30}
def test_remaining_time_tracks_battery_direction_and_missing_estimates():
dev = device()
dev._record(report(display_payload()))
dev._record(report(floating(158, -64)))
assert dev.snapshot.bms_charge_is_charging.raw_value is False
assert dev.snapshot.bms_charge_is_discharging.raw_value is True
assert dev.snapshot.ef_remaining_time_minutes.raw_value == 184
dev._record(report(integer(268, 0xFFFFFFFF)))
assert dev.snapshot.ef_discharge_remaining_time_minutes is None
assert dev.snapshot.ef_remaining_time_minutes is None
dev._record(report(integer(268, 0)))
assert dev.snapshot.ef_remaining_time_minutes.raw_value == 0
dev._record(report(floating(158, 0)))
assert dev.snapshot.ef_remaining_time_minutes is None
def test_no_load_sample_matches_display_hours_without_changing_minute_units():
# Synthetic message using observed measurements, without device identifiers.
# The display showed 89% and 75–76 hours, not 75–76 minutes.
dev = device()
dev._record(report(b"".join([
floating(262, 89), floating(3, 0), floating(4, 0),
floating(158, -1), integer(259, 29), integer(268, 4556),
integer(269, 4559), integer(282, 0),
])))
# A later configuration-only update must not erase these measurements.
dev._record(report(integer(363, 1)))
snap = dev.snapshot
assert snap.bms_capacity_charge_ratio.raw_value == pytest.approx(0.89)
assert snap.bms_temperature_celsius.raw_values == {1: 29}
assert snap.ef_input_power_watts.raw_value == 0
assert snap.ef_output_power_watts.raw_value == 0
assert snap.bms_charge_is_charging.raw_value is False
assert snap.bms_charge_is_discharging.raw_value is True
assert snap.ef_charge_state.raw_value == 0
assert snap.ef_charge_remaining_time_minutes.raw_value == 4559
assert snap.ef_discharge_remaining_time_minutes.raw_value == 4556
assert snap.ef_remaining_time_minutes.raw_value == 4556
assert snap.ef_remaining_time_minutes.units == "min"
assert divmod(snap.ef_remaining_time_minutes.raw_value, 60) == (75, 56)
def test_usb_load_sample_uses_battery_power_not_river2_state_codes():
# Observed values encoded into a synthetic report. River 3 reported state 1
# while discharging; River 2 uses state 1 for charging.
dev = device()
dev._record(report(b"".join([
floating(262, 89), floating(3, 0), floating(4, 14),
floating(11, -14.322), floating(158, -16), integer(259, 29),
integer(268, 754), integer(269, 802), integer(281, 1), integer(282, 1),
])))
snap = dev.snapshot
assert snap.bms_capacity_charge_ratio.raw_value == pytest.approx(0.89)
assert snap.ef_input_power_watts.raw_value == 0
assert snap.ef_output_power_watts.raw_value == 14
assert snap.bms_charge_is_charging.raw_value is False
assert snap.bms_charge_is_discharging.raw_value is True
assert snap.ef_charge_state.raw_value == 1
assert snap.ef_remaining_time_minutes.raw_value == 754
assert snap.ef_charge_remaining_time_minutes.raw_value == 802
assert divmod(snap.ef_remaining_time_minutes.raw_value, 60) == (12, 34)
def test_river2_time_convention_is_not_assumed_for_river3():
dev = device()
dev._record(report(floating(158, -1) + integer(268, 5999)))
assert dev.snapshot.ef_discharge_remaining_time_minutes.raw_value == 5999
@pytest.mark.parametrize("invalid", [float("nan"), float("inf"), float("-inf")])
def test_nonfinite_measurements_are_not_exported(invalid):
dev = device()
dev._record(report(b"".join(floating(field, invalid) for field in (262, 3, 4, 158))))
assert dev.snapshot.bms_capacity_charge_ratio is None
assert dev.snapshot.ef_input_power_watts is None
assert dev.snapshot.ef_output_power_watts is None
assert dev.snapshot.bms_charge_is_charging is None
@pytest.mark.parametrize("soc", [-1, 101])
def test_invalid_soc_and_negative_total_power_are_not_exported(soc):
dev = device()
dev._record(report(floating(262, soc) + floating(3, -1) + floating(4, -2)))
assert dev.snapshot.bms_capacity_charge_ratio is None
assert dev.snapshot.ef_input_power_watts is None
assert dev.snapshot.ef_output_power_watts is None
@pytest.mark.parametrize("version", [3, 0x13])
def test_encrypted_xor_reports_survive_notification_fragmentation(version):
pytest.importorskip("Crypto")
enc = _Type7Encryption(bytes(range(16)), bytes(range(16, 32)))
payload = display_payload(power=-64)
key = 0x75
pkt = EcoFlowPacket(
2, 0x21, 0xFE, 0x15, bytes(b ^ key for b in payload),
version=version, seq=bytes([key, 0, 0, 0]),
)
wire = _EncFrameHelper(enc).encode(pkt)
async def run():
for split in range(1, len(wire)):
dev = device()
dev._state = _State.AUTHENTICATED
dev._assembler = _EncFrameHelper(enc, xor_payload=dev._is_river3)
await dev._on_data(bytearray(wire[:split]))
assert dev.snapshot.ef_input_power_watts is None
await dev._on_data(bytearray(wire[split:]))
assert dev.snapshot.ef_input_power_watts.raw_value == 244
assert dev.snapshot.bms_charge_is_discharging.raw_value is True
assert dev.snapshot._packets["ef_pkt_02_fe_15"].info == payload.hex()
asyncio.run(run())
def test_river2_payload_is_not_xored():
pytest.importorskip("Crypto")
enc = _Type7Encryption(bytes(16), bytes(16))
dev = device("R601TEST00000001")
helper = _EncFrameHelper(enc, xor_payload=dev._is_river3)
pkt = EcoFlowPacket(2, 0x21, 0x20, 2, b"plain", seq=b"\x75\x00\x00\x00", version=2)
assert helper.decode(helper.encode(pkt))[0].payload == b"plain"
def test_collection_waits_for_partial_measurements_not_unconfirmed_runtime(monkeypatch, capsys):
path = Path(__file__).resolve().parents[1] / "tools" / "ecoflow-bt.py"
spec = importlib.util.spec_from_file_location("ecoflow_diagnostic_river3", path)
script = importlib.util.module_from_spec(spec)
spec.loader.exec_module(script)
dev = device()
fragments = iter([floating(262, 50), display_payload()])
async def receive(_):
dev._record(report(next(fragments)))
sleep = AsyncMock(side_effect=receive)
monkeypatch.setattr(script.asyncio, "sleep", sleep)
expected = script.MODEL_PROFILES["R651"]["expected_fields"]
assert "ef_pkt_02_fe_16" not in expected
asyncio.run(script.collect([(ADDRESS, dev, expected)], max_wait=1))
assert sleep.await_count == 2
assert "complete (1 packet type(s))" in capsys.readouterr().out