"""Synthetic River 2 diagnostics. No device captures or private identifiers."""
|
|
|
|
import asyncio
|
|
import importlib.util
|
|
import struct
|
|
from argparse import Namespace
|
|
from pathlib import Path
|
|
from unittest.mock import AsyncMock, Mock
|
|
|
|
import pytest
|
|
|
|
from bmspy.ecoflow_bt import EcoFlowBTDevice, EcoFlowPacket, _State
|
|
|
|
ADDRESS = "02:00:00:00:00:03"
|
|
|
|
@pytest.fixture
|
|
def script():
|
|
path = Path(__file__).resolve().parents[1] / "tools" / "ecoflow-bt.py"
|
|
spec = importlib.util.spec_from_file_location("ecoflow_live_diagnostics", path)
|
|
module = importlib.util.module_from_spec(spec)
|
|
spec.loader.exec_module(module)
|
|
return module
|
|
|
|
|
|
def device(prefix="R601"):
|
|
return EcoFlowBTDevice(ADDRESS, prefix + "TEST00000001", "test-user")
|
|
|
|
|
|
def attach(script, dev, watch=False):
|
|
collector = script.PacketCollector(ADDRESS, script.MODEL_PROFILES[dev.serial_number[:4]], watch)
|
|
dev.on_packet(collector.receive)
|
|
return collector
|
|
|
|
|
|
def river2_bypass_packets():
|
|
"""Synthetic first burst: three core heartbeats, MPPT, and an empty reply."""
|
|
pd = bytearray(121)
|
|
struct.pack_into("<BHHi", pd, 14, 88, 35, 35, 5218)
|
|
ems = bytearray(46)
|
|
struct.pack_into("<II", ems, 17, 5999, 5999)
|
|
struct.pack_into("<f", ems, 26, 87.5)
|
|
bms = bytearray(69)
|
|
bms[11], bms[20] = 88, 28
|
|
struct.pack_into("<I", bms, 12, 13)
|
|
struct.pack_into("<fIII", bms, 53, 87.75, 0, 0, 0)
|
|
return [
|
|
EcoFlowPacket(2, 0x21, 0x20, 2, bytes(pd), version=2),
|
|
EcoFlowPacket(0x35, 0x21, 1, 0x52, b"", version=2),
|
|
EcoFlowPacket(3, 0x21, 0x20, 2, bytes(ems), version=2),
|
|
EcoFlowPacket(3, 0x21, 0x20, 0x32, bytes(bms), version=2),
|
|
EcoFlowPacket(5, 0x21, 0x20, 2, bytes(94), version=2),
|
|
]
|
|
|
|
|
|
def test_river2_finishes_on_first_heartbeat_set_with_same_snapshot_format(script, monkeypatch, capsys):
|
|
dev = device("R601")
|
|
# Include optional INV/MPPT packets in the initial burst as well as the three
|
|
# core heartbeats. Normal River 2 output and required packet types stay intact.
|
|
for src, cmd_id in [(2, 2), (3, 2), (3, 0x32), (4, 2), (5, 2)]:
|
|
dev._record(EcoFlowPacket(src, 0x21, 0x20, cmd_id, bytes(128), version=2))
|
|
expected = script.MODEL_PROFILES["R601"]["expected_fields"]
|
|
sleep = AsyncMock(side_effect=AssertionError("must not wait"))
|
|
monkeypatch.setattr(script.asyncio, "sleep", sleep)
|
|
asyncio.run(script.collect([(ADDRESS, dev, expected)], max_wait=120))
|
|
script.print_snapshot("River 2", ADDRESS, dev.snapshot, [2, 3, 4, 5])
|
|
sleep.assert_not_awaited()
|
|
out = capsys.readouterr().out
|
|
assert "3/3 required heartbeats received (PD, EMS, BMS)" in out
|
|
assert "Optional heartbeat types seen: INV, MPPT. Not seen: none (not required)" in out
|
|
for message in ("PD heartbeat", "EMS heartbeat", "BMS heartbeat", "INV heartbeat", "MPPT heartbeat"):
|
|
assert message in out
|
|
assert "latest fields collected" not in out
|
|
|
|
|
|
@pytest.mark.parametrize("prefix", ["R601", "R603"])
|
|
def test_river2_bypass_burst_without_inverter_finishes_immediately(script, monkeypatch, capsys, prefix):
|
|
dev = device(prefix)
|
|
collector = attach(script, dev)
|
|
for packet in river2_bypass_packets():
|
|
dev._record(packet)
|
|
expected = script.MODEL_PROFILES[prefix]["expected_fields"]
|
|
sleep = AsyncMock(side_effect=AssertionError("must not wait for optional INV"))
|
|
monkeypatch.setattr(script.asyncio, "sleep", sleep)
|
|
asyncio.run(script.collect([(ADDRESS, dev, expected)], max_wait=120, collectors={ADDRESS: collector}))
|
|
script.print_snapshot("River 2", ADDRESS, dev.snapshot, [2, 3, 4, 5])
|
|
sleep.assert_not_awaited()
|
|
out = capsys.readouterr().out
|
|
assert "3/3 required heartbeats received (PD, EMS, BMS)" in out
|
|
assert "Optional heartbeat types seen: MPPT. Not seen: INV (not required)" in out
|
|
assert "Other packet types seen: ef_pkt_35_01_52 (empty payload)" in out
|
|
assert "5 packet type(s)" not in out
|
|
assert "[INV heartbeat]" not in out
|
|
for message in ("PD heartbeat", "EMS heartbeat", "BMS heartbeat", "MPPT heartbeat"):
|
|
assert message in out
|
|
snap = dev.snapshot
|
|
assert snap.ef_packets_received.raw_value == 5
|
|
assert snap.bms_capacity_charge_ratio.raw_value == pytest.approx(0.8775)
|
|
assert snap.bms_temperature_celsius.raw_values == {1: 28}
|
|
assert snap.bms_charge_is_charging.raw_value is False
|
|
assert snap.bms_charge_is_discharging.raw_value is False
|
|
assert snap.ef_input_power_watts.raw_value == snap.ef_output_power_watts.raw_value == 35
|
|
assert snap.ef_remaining_time_minutes.raw_value == 5218
|
|
assert snap.ef_charge_remaining_time_minutes is None
|
|
assert snap.ef_discharge_remaining_time_minutes is None
|
|
assert "chg_remain_time: 5999 min" in out
|
|
assert "dsg_remain_time: 5999 min" in out
|
|
|
|
|
|
@pytest.mark.parametrize("index,minimum,label", [(0, 23, "PD"), (2, 25, "EMS"), (3, 21, "BMS")])
|
|
@pytest.mark.parametrize("empty", [False, True])
|
|
@pytest.mark.parametrize("listen", [False, True])
|
|
def test_invalid_river2_heartbeat_cannot_complete_collection(
|
|
script, capsys, index, minimum, label, empty, listen,
|
|
):
|
|
dev = device("R601")
|
|
collectors = {ADDRESS: attach(script, dev)} if listen else {}
|
|
packets = river2_bypass_packets()
|
|
valid = packets[index]
|
|
packets[index] = EcoFlowPacket(valid.src, valid.dst, valid.cmd_set, valid.cmd_id,
|
|
b"" if empty else valid.payload[:minimum - 1], version=2)
|
|
for packet in packets:
|
|
dev._record(packet)
|
|
expected = script.MODEL_PROFILES["R601"]["expected_fields"]
|
|
asyncio.run(script.collect([(ADDRESS, dev, expected)], max_wait=0, collectors=collectors))
|
|
out = capsys.readouterr().out
|
|
assert "timed out, incomplete" in out
|
|
assert f"{label} (ef_pkt_" in out
|
|
assert "3/3 required heartbeats received" not in out
|
|
dev._record(valid)
|
|
asyncio.run(script.collect([(ADDRESS, dev, expected)], max_wait=0, collectors=collectors))
|
|
assert "3/3 required heartbeats received" in capsys.readouterr().out
|
|
|
|
|
|
def test_river2_valid_heartbeat_stays_received_after_a_later_bad_packet(script, capsys):
|
|
dev = device("R601")
|
|
collector = attach(script, dev)
|
|
packets = river2_bypass_packets()
|
|
dev._record(packets[0])
|
|
dev._record(EcoFlowPacket(2, 0x21, 0x20, 2, b"", version=2))
|
|
for packet in packets[1:]:
|
|
dev._record(packet)
|
|
expected = script.MODEL_PROFILES["R601"]["expected_fields"]
|
|
asyncio.run(script.collect([(ADDRESS, dev, expected)], max_wait=0, collectors={ADDRESS: collector}))
|
|
assert "3/3 required heartbeats received" in capsys.readouterr().out
|
|
|
|
|
|
def test_river2_accepts_zero_values_and_minimum_valid_core_lengths(script, capsys):
|
|
dev = device("R601")
|
|
for src, cmd_id, size in [(2, 2, 23), (3, 2, 25), (3, 0x32, 21)]:
|
|
dev._record(EcoFlowPacket(src, 0x21, 0x20, cmd_id, bytes(size), version=2))
|
|
asyncio.run(script.collect([(ADDRESS, dev, script.MODEL_PROFILES["R601"]["expected_fields"])], max_wait=0))
|
|
out = capsys.readouterr().out
|
|
assert "3/3 required heartbeats received" in out
|
|
assert "Not seen: INV, MPPT (not required)" in out
|
|
|
|
|
|
def test_packet_listeners_receive_duplicates_after_snapshot_updates():
|
|
dev = device()
|
|
observed = []
|
|
dev.on_packet(Mock(side_effect=ValueError("bad listener")))
|
|
dev.on_packet(lambda pkt: observed.append((pkt, dev.snapshot.ef_input_power_watts.raw_value)))
|
|
updated = Mock()
|
|
dev.on_update(updated)
|
|
pkt = river2_bypass_packets()[0]
|
|
dev._record(pkt)
|
|
dev._record(pkt)
|
|
assert observed == [(pkt, 35), (pkt, 35)]
|
|
assert updated.call_count == 2
|
|
|
|
|
|
def test_river2_watch_keeps_late_unknown_packets_after_completion(script, monkeypatch, capsys):
|
|
dev = device()
|
|
dev._state = _State.AUTHENTICATED
|
|
collector = attach(script, dev, watch=True)
|
|
for packet in river2_bypass_packets():
|
|
dev._record(packet)
|
|
calls = 0
|
|
|
|
async def receive_later(_):
|
|
nonlocal calls
|
|
calls += 1
|
|
if calls == 1:
|
|
dev._record(EcoFlowPacket(0x35, 0x21, 0x35, 0x20, b"synthetic-unknown"))
|
|
else:
|
|
raise asyncio.CancelledError()
|
|
|
|
monkeypatch.setattr(script.asyncio, "sleep", receive_later)
|
|
expected = script.MODEL_PROFILES["R601"]["expected_fields"]
|
|
with pytest.raises(asyncio.CancelledError):
|
|
asyncio.run(script.collect([(ADDRESS, dev, expected)], max_wait=0,
|
|
collectors={ADDRESS: collector}, watch=True))
|
|
out = capsys.readouterr().out
|
|
assert calls == 2
|
|
assert "3/3 required heartbeats received" in out
|
|
assert "continuing watch for optional or unknown information" in out
|
|
assert "raw_payload: " + b"synthetic-unknown".hex() in out
|
|
assert "timed out" not in out
|
|
|
|
|
|
@pytest.mark.parametrize("failure", [None, "cancel", "output", "disconnect"])
|
|
def test_river2_run_listens_before_connect_and_always_disconnects(script, monkeypatch, capsys, failure):
|
|
dev = device()
|
|
|
|
async def connect(**_):
|
|
dev._state = _State.AUTHENTICATED
|
|
packets = river2_bypass_packets()
|
|
dev._record(packets[0])
|
|
# Valid receipt must survive a later bad packet even before collect starts.
|
|
dev._record(EcoFlowPacket(2, 0x21, 0x20, 2, b"", version=2))
|
|
for packet in packets[1:]:
|
|
dev._record(packet)
|
|
if failure == "disconnect":
|
|
dev._state = _State.DISCONNECTED
|
|
|
|
manager = Mock(add_device=Mock(return_value=dev), connect_all=AsyncMock(side_effect=connect),
|
|
disconnect_all=AsyncMock())
|
|
monkeypatch.setattr(script, "EcoFlowBTManager", Mock(return_value=manager))
|
|
if failure == "cancel":
|
|
monkeypatch.setattr(script.asyncio, "sleep", AsyncMock(side_effect=asyncio.CancelledError()))
|
|
if failure == "output":
|
|
monkeypatch.setattr(script.PacketCollector, "_receive", Mock(side_effect=OSError("output failed")))
|
|
args = Namespace(scan=False, device=ADDRESS, serial_number=dev.serial_number,
|
|
debug=0, timeout=0, watch=bool(failure))
|
|
if failure:
|
|
error = {"cancel": asyncio.CancelledError, "output": OSError, "disconnect": ConnectionError}[failure]
|
|
with pytest.raises(error):
|
|
asyncio.run(script.run("test-user", args))
|
|
else:
|
|
asyncio.run(script.run("test-user", args))
|
|
assert "3/3 required heartbeats received" in capsys.readouterr().out
|
|
manager.disconnect_all.assert_awaited_once()
|
|
|
|
|
|
@pytest.mark.parametrize("value", ["", "not-hex", None, 123])
|
|
def test_river2_snapshot_validation_rejects_invalid_hex(script, value):
|
|
collector = script.PacketCollector(ADDRESS, script.MODEL_PROFILES["R601"])
|
|
snapshot = Mock()
|
|
snapshot.items.return_value = [(key, Mock(info=value)) for key in script.RIVER2_REQUIRED_HEARTBEATS]
|
|
collector.observe_snapshot(snapshot)
|
|
assert len(collector.missing()) == 3
|
|
|