tim 6b636cde81 Report a device that sends no data for 5 minutes
If the server had no data for the device, bmspy-ups slept and read again with no report. A battery that stopped answering during a power failure gave no email and no shutdown.

bmspy-ups now sends one email after 5 minutes with no data, and one more when the data returns. A new email for a loss needs another 5 minutes with no data after that return. The same rule applies to the wait at startup.
2026-10-10 11:05:16 +02:00
2026-10-08 14:03:09 +02:00
2021-02-03 11:19:58 +00:00
2026-10-10 10:59:34 +02:00
2026-10-08 14:03:09 +02:00

bmspy

bmspy is a tool to get information from battery management systems and UPS devices. It supports:

  • Xiaoxiang-type BMS devices via serial (USB)
  • EcoFlow power stations via Bluetooth LE

It can display the information as text, in JSON, or export the data continuously to InfluxDB or a Prometheus exporter.

Multiple devices can be connected at once. Each is identified by a name. Data from all of them (or just one) can be pushed to InfluxDB or Prometheus in the same connection. Each measurement is tagged with the device name.

Install uv and use Python 3.12 or later, below Python 4. Then create the local environment:

git clone https://git.treehouse.org.za/tim/bmspy
cd bmspy
uv sync --locked

To install with EcoFlow Bluetooth LE support:

uv sync --locked --extra ecoflow-bt

To install with InfluxDB and Prometheus support:

uv sync --locked --extra influxdb --extra prometheus

These optional dependency sets are called extras. Select the required extras with each uv run command, or use --all-extras to enable all of them. uv sync also installs development dependencies by default. Use --no-dev for a deployment that does not need the test tools.

Running the server

The server daemon reads from one or more devices and makes the data available over a Unix socket.

Single JBD BMS device (defaults to /dev/ttyUSB0):

uv run bmspy-server

Multiple JBD BMS devices, with optional names (default name is derived from the device path, for example ttyUSB0):

uv run bmspy-server -d network:/dev/ttyUSB0 -d nas:/dev/ttyUSB1

EcoFlow Bluetooth LE devices

Install the ecoflow-bt extra as shown above. Close the EcoFlow app and stop other Bluetooth collectors before connecting to a device.

Setup

Get your EcoFlow account user ID:

uv run bmspy-ecoflow-login you@example.com

The command prompts for your password. If needed, add --region EU or --region US. Use the diagnostic scan below to find device addresses and serial numbers.

Type 7 authentication also needs an external lookup table from ha-ef-ble. From the bmspy repository root, download it:

curl --fail --location --output bmspy/ecoflow_keydata.py \
  https://raw.githubusercontent.com/rabits/ha-ef-ble/main/custom_components/ef_ble/eflib/keydata.py

This file is ignored by Git and excluded from packages. Type 1 devices do not need it.

Dump both Rivers

Device arguments use name@ADDRESS/SERIAL/USERID. Replace the placeholders below with each device's Bluetooth address, serial number, and your account user ID:

uv run --extra ecoflow-bt bmspy-server --socket /tmp/bmspy-rivers.sock \
  -d 'river2@RIVER2_MAC/RIVER2_SERIAL/YOUR_USER_ID' \
  -d 'river3@RIVER3_MAC/RIVER3_SERIAL/YOUR_USER_ID'

Leave the server running. In another terminal, print both snapshots:

uv run bmspy --socket /tmp/bmspy-rivers.sock

Omit --ups for all devices. Add --ups river2 to select one. --ups all means a device named all, not all devices. To include a serial BMS, add a server argument such as -d network:/dev/ttyUSB0.

The server reads each device in its own background thread, so a slow or offline device does not delay the other devices or the clients. It reads one Bluetooth device at a time and waits 60 seconds after each Bluetooth read, including a failed one. It reads a serial BMS every 5 seconds and retries a failed serial read after 1 second. Unavailable devices are omitted from the response. Only the first request after startup waits, until each device completes one read attempt.

The server answers each client in its own thread, so a slow client does not delay the other clients. It closes a connection that stays silent for 5 seconds.

Each Bluetooth read listens for 10 seconds. If a required report is still missing, the read continues until the report arrives, for at most 30 seconds in total. A read that reaches this limit returns a partial snapshot. Its ef_missing_measurements field names the missing reports, and the server log shows one line each time that list changes.

Diagnostics

Stop the server before connecting directly. Scan and collect reports from both Rivers:

uv run --extra ecoflow-bt python -u tools/ecoflow-bt.py --user-id YOUR_USER_ID --scan --timeout 30

Add --watch to print every packet until Ctrl+C. Watch mode ignores the telemetry timeout, but stops on a lost connection. Its payloads are already decrypted. Keep diagnostic output private because it can contain device and account identifiers.

The scan detects encryption automatically. To select one discovered device, add --device ADDRESS. Without scanning, replace --scan with --device ADDRESS --serial-number SERIAL. Direct connections default to Type 7. Session keys stay internal. The script has no encryption override or key-export option.

River 2 collection waits for three valid core reports, not optional inverter or solar reports. River 3 waits for 53 baseline fields across several reports. These checks do not guarantee every possible field. A timeout reports incomplete collection. Use --watch to receive later reports.

Both models report charge, temperature, power, and time estimates through separate decoders. Missing measurements stay absent. See the River 2 measurement reference and River 3 field reference for units, decoding rules, and known limits.

Client snapshots also include reported protocol fields under ef_river2_* and ef_river3_display_*, alongside the shared measurements and raw packets. Partial reports retain earlier field values. Nested River 3 groups use JSON text in their info fields. The references above describe names, units, and limits.

Running via systemd

Before you start a service, install its dependencies in the service's working directory with uv sync --locked --no-dev. Add --extra ecoflow-bt for Bluetooth, --extra influxdb for InfluxDB, or both.

The service files use uv run --no-sync. With this option, a service does not change the shared environment at startup. If the uv executable is not on systemd's search path, set it to an absolute path.

Copy bmspy-server.service to /etc/systemd/system, adjust WorkingDirectory and the ExecStart line as needed, then enable and start it:

cp bmspy-server.service /etc/systemd/system
$EDITOR /etc/systemd/system/bmspy-server.service
systemctl daemon-reload
systemctl enable bmspy-server
systemctl start bmspy-server

Running a client

To print a summary of all connected devices:

uv run bmspy

To show only a specific device:

uv run bmspy --ups network

To push data for all devices to InfluxDB (each measurement is tagged ups=<name>):

uv run --extra influxdb bmspy-influxdb --url https://influx.example.com --org myorg --token mytoken

To push data for a single device only:

uv run --extra influxdb bmspy-influxdb --ups network --url ...

InfluxDB connection details can also be supplied via environment variables (INFLUXDB_V2_URL, INFLUXDB_V2_ORG, INFLUXDB_V2_TOKEN) instead of command-line flags.

Development

Install all extras and run the tests:

uv sync --locked --all-extras
uv run --locked --all-extras pytest

To build a source archive and a wheel, which is an installable Python package:

uv build

uv.lock records the resolved dependency versions. After you change dependencies in pyproject.toml, run uv lock and include the updated lock file with the change.

S
Description
bmspy can be used to get information from a xiaoxiang-type BMS system.
Readme CC-BY-SA-4.0