tim aa9888800e Report EcoFlow power and temperature as floats
River 2 reported total power and temperature as integers. River 3 reported temperature as an integer. InfluxDB keeps one field type for each measurement, so it rejected these points when another device wrote floats to the same measurement.
2026-10-10 09:03:33 +02:00
tim f36bb2510c Rename bms_temperature_celcius to bms_temperature_celsius
Correct the spelling in the JBD and EcoFlow snapshots, the diagnostic tool, and the tests. UPS.from_dict maps the old name to the new name, so a client still reads data from an older server during an upgrade.

InfluxDB and Prometheus now receive this measurement under the new name.
2026-10-10 09:03:33 +02:00
tim 5fa6000c70 Separate JBD decoding from serial transport
Move response decoding into jbd_proto and the data container into jbd_snapshot. Preserve the existing jbd_bms imports and test the transport boundary.
2026-10-08 14:09:05 +02:00
tim c2faeb669a Add River 3 telemetry and schema-based diagnostics
Decode River 3 separately and accumulate partial reports against a field-level checklist. Keep watch mode running after completion.

Label fields and nested records from the pinned pr705 schema. Preserve unknown values and document unverified meanings and routing.

Add synthetic regressions, the River 3 field reference, schema-generation tooling, and upstream attribution.
2026-10-08 14:08:20 +02:00