tim 9ab1d909ed Raise a clear client error for a refused request
socket_comms now raises DaemonError with the server message if the reply has the status ERROR. Before, the reply reached code that expects device data, and that code raised KeyError.
2026-10-10 10:59:35 +02:00
tim 0d5a080425 Read each request in full
read_request called recv once for the length and once for the body. A stream socket can deliver a request in several pieces, and the server then rejected that request.

The server now uses the read loop of the client, which moves to utilities as recv_exact. The server refuses a request above 64 KiB.
2026-10-10 10:59:34 +02:00
tim f17d1d82c2 Answer each client in its own thread
The server handled one client at a time, so a client that connected and sent nothing blocked every other client. The request handling is now in handle_client, and the main loop starts one thread for each connection.

The server closes a connection that stays silent for 5 seconds, so its thread ends.
2026-10-10 10:59:34 +02:00
tim 6ee9bbaca8 Keep the server running if a reply fails
If a client disconnected before its reply, send_response raised OSError and the server ended. The request loop now logs the error and waits for the next client. An error from accept() still ends the server.
2026-10-10 10:59:34 +02:00
tim 0abc8536f0 Answer an invalid request with an error reply
An unknown command ended the server loop, so one bad request stopped the service for every client. The server now sends {"status": "ERROR", "message": ...} and continues. A request with no command, or one that is not a JSON object, gets the same reply.

The server tests stopped the server with an unknown command. They now stop it through accept().
2026-10-10 10:59:34 +02:00
tim bf2d96140b Test a failed JBD read
collect_data returns False if requestMessage returns False or None, for the first request and for the second one. Before the earlier fix, these values raised TypeError and ended the server.
2026-10-10 10:59:34 +02:00
tim 82def5737f Select the bmspy-ups device from the configured devices
bmspy-ups selected its device from the devices that had data at startup, and exited with status 0 if the selection failed. One failed first read ended the monitor or made it select the wrong device.

The server has a new DEVICES command that lists the configured names, and client.list_devices calls it. bmspy-ups selects from that list and then waits for the first data of its device. A wrong or missing --device now exits with status 2. The service file does not restart on that status, because a restart cannot correct it.

An older server ends on the unknown DEVICES command, so update the server first.
2026-10-10 09:03:35 +02:00
tim 161ae7ee65 Wait for the required EcoFlow reports in each collection
A Bluetooth collection listened for a fixed 10 seconds and returned the data that arrived. If a required report was late, the snapshot missed shared measurements without notice.

Each decoder now tracks the reports behind the shared measurements. A collection listens for 10 seconds, then until those reports arrive, for at most 30 seconds in total. The new ef_missing_measurements field names the reports that did not arrive. The server log shows one line each time that list changes.

The diagnostic tool now uses the River 2 heartbeat list from the decoder.
2026-10-10 09:03:35 +02:00
tim b569bcf27b Fix email, shutdown, and option bugs in bmspy-ups
The recipient check used a regular expression that never matched, so a full address got the host name appended. The main loop passed the device name with a parameter name that read_data does not have. A canceled shutdown did not clear its flag, so a second incident did not schedule a shutdown. The recorded shutdown time used the wrong unit. The --port option stayed text and never matched the STARTTLS ports.
2026-10-10 09:03:34 +02:00
tim 953f8a6482 Read each device in a background thread
A failed JBD read retried forever inside a client request and blocked every other device and client. The server now starts one polling thread for each device, and a request returns the last snapshot. Only the first request after startup waits, until each device completes one read attempt.

One lock makes sure that only one Bluetooth collection runs at a time. A serial BMS retries a failed read after 1 second and keeps its last snapshot for 30 seconds. An error in a collection does not end the polling of that device.
2026-10-10 09:03:34 +02:00
tim d86d59c0f7 Stop the server thread at the end of each server test
The server tests left main() in a thread after each test. These threads kept their patches active and delayed the suite. Each test now sends an invalid command, which ends the server loop, and then joins the thread. The suite time drops from about 8.5 seconds to about 2 seconds.

Remove one unused line from a test.
2026-10-10 09:03:34 +02:00
tim aa9888800e Report EcoFlow power and temperature as floats
River 2 reported total power and temperature as integers. River 3 reported temperature as an integer. InfluxDB keeps one field type for each measurement, so it rejected these points when another device wrote floats to the same measurement.
2026-10-10 09:03:33 +02:00
tim f36bb2510c Rename bms_temperature_celcius to bms_temperature_celsius
Correct the spelling in the JBD and EcoFlow snapshots, the diagnostic tool, and the tests. UPS.from_dict maps the old name to the new name, so a client still reads data from an older server during an upgrade.

InfluxDB and Prometheus now receive this measurement under the new name.
2026-10-10 09:03:33 +02:00
tim 452a3bc207 Correct the ups_alarm field spelling
The upstream River 3 schema spells field 355 `ups_alram`. Use `ups_alarm` in the decoder, the generated schema, and the field reference. The schema generator now applies a rename map, so a regenerated schema keeps the corrected name.
2026-10-10 09:03:32 +02:00
tim 5fa6000c70 Separate JBD decoding from serial transport
Move response decoding into jbd_proto and the data container into jbd_snapshot. Preserve the existing jbd_bms imports and test the transport boundary.
2026-10-08 14:09:05 +02:00
tim 3422742204 Fix server SIGTERM handler signature 2026-10-08 14:08:20 +02:00
tim c2faeb669a Add River 3 telemetry and schema-based diagnostics
Decode River 3 separately and accumulate partial reports against a field-level checklist. Keep watch mode running after completion.

Label fields and nested records from the pinned pr705 schema. Preserve unknown values and document unverified meanings and routing.

Add synthetic regressions, the River 3 field reference, schema-generation tooling, and upstream attribution.
2026-10-08 14:08:20 +02:00
tim 79f9ebf0c7 Integrate EcoFlow Bluetooth devices into the server
Serial paths and collector interfaces remain compatible. Bluetooth polling uses a 60-second cache and backoff. Offline Bluetooth devices no longer retry forever inside a client request. Invalid device specifications do not echo account IDs.
2026-10-08 14:02:45 +02:00
tim 886991caf3 Add River 2 Bluetooth telemetry and diagnostics
Decode River 2 charge, temperature, power flow, and time estimates. Preserve precise charge readings across packet reordering and omit unavailable time estimates.

Require valid PD, EMS, and BMS core heartbeats for diagnostic completion. Report optional packets separately and support raw watch output with reliable disconnect cleanup. Use synthetic regression tests and keep captures, credentials, and external keydata private.

Device details come from command-line arguments or discovery. This commit retains Poetry; the separate packaging commit migrates to uv.
2026-10-08 14:02:45 +02:00
tim 90388d2800 Stop Prometheus mode from falling through to the client 2026-10-07 17:44:48 +02:00
tim 75564f96f0 Fix UPS functionality for multiple devices 2026-05-02 23:25:15 +02:00
tim 897ae5dfb7 Add unit tests 2026-05-02 23:12:29 +02:00