tim 99f3d41970 Show the present state of each device first in the Grafana dashboard
The dashboard started with gauges and histories of equal weight, so a power failure and its effect were hard to find. The first rows now show the charge, the power source, the time remaining, and the errors of each device. Below them, one band shows each period on battery power, and one chart shows the charge of the three devices.

The charge history adds the pack current of the JBD and the River 2 on a right axis, as dashed lines in the color of each device. The charge limits apply to the charge lines only.

A time-remaining panel with no estimate now names the state. The JBD panel shows "On mains" while the pack does not discharge. The River 2 panel shows "Idle" while the device reports 5999 minutes for the two directions.

The River 2 errors panel names the module that reports a code and shows the code in hexadecimal. The solar controller reports 4096 with no solar input, and the panel counts that value as zero.
2026-10-13 12:48:03 +02:00
tim e32d3a8e22 Add a Grafana dashboard generator for the three UPS devices
tools/generate_grafana_ups.py writes grafana-ups.json, which shows the JBD network UPS, the River 2 desktop UPS, and the River 3 NAS UPS in three columns. Git ignores the generated file.

Each EcoFlow column shows one time-remaining panel in hours, for the direction in use. The River 2 histories add pack current and remaining capacity. The River 3 reports neither, so its histories add battery power and charge.
2026-10-10 11:56:29 +02:00
tim 161ae7ee65 Wait for the required EcoFlow reports in each collection
A Bluetooth collection listened for a fixed 10 seconds and returned the data that arrived. If a required report was late, the snapshot missed shared measurements without notice.

Each decoder now tracks the reports behind the shared measurements. A collection listens for 10 seconds, then until those reports arrive, for at most 30 seconds in total. The new ef_missing_measurements field names the reports that did not arrive. The server log shows one line each time that list changes.

The diagnostic tool now uses the River 2 heartbeat list from the decoder.
2026-10-10 09:03:35 +02:00
tim f36bb2510c Rename bms_temperature_celcius to bms_temperature_celsius
Correct the spelling in the JBD and EcoFlow snapshots, the diagnostic tool, and the tests. UPS.from_dict maps the old name to the new name, so a client still reads data from an older server during an upgrade.

InfluxDB and Prometheus now receive this measurement under the new name.
2026-10-10 09:03:33 +02:00
tim 452a3bc207 Correct the ups_alarm field spelling
The upstream River 3 schema spells field 355 `ups_alram`. Use `ups_alarm` in the decoder, the generated schema, and the field reference. The schema generator now applies a rename map, so a regenerated schema keeps the corrected name.
2026-10-10 09:03:32 +02:00
tim c2faeb669a Add River 3 telemetry and schema-based diagnostics
Decode River 3 separately and accumulate partial reports against a field-level checklist. Keep watch mode running after completion.

Label fields and nested records from the pinned pr705 schema. Preserve unknown values and document unverified meanings and routing.

Add synthetic regressions, the River 3 field reference, schema-generation tooling, and upstream attribution.
2026-10-08 14:08:20 +02:00
tim bac953bf48 Replace Poetry with uv
Use standard project metadata, dependency groups, and the uv build backend. The new lock preserves the previous dependency versions. Documentation and services use uv, and services leave their shared environment unchanged at startup.

Remove the entry point for the empty USB HID prototype. Exclude local prototypes, captures, and the external Type 7 lookup table from version control and distributions.
2026-10-08 14:03:09 +02:00
tim 886991caf3 Add River 2 Bluetooth telemetry and diagnostics
Decode River 2 charge, temperature, power flow, and time estimates. Preserve precise charge readings across packet reordering and omit unavailable time estimates.

Require valid PD, EMS, and BMS core heartbeats for diagnostic completion. Report optional packets separately and support raw watch output with reliable disconnect cleanup. Use synthetic regression tests and keep captures, credentials, and external keydata private.

Device details come from command-line arguments or discovery. This commit retains Poetry; the separate packaging commit migrates to uv.
2026-10-08 14:02:45 +02:00