tim 0c179d29e5 Disconnect from Bluetooth devices before the server stops
The polling threads are daemon threads, so a stop ended the server in the middle of a Bluetooth read. The read got no disconnect, and the adapter kept an open connection or a scan in progress.

The server now sets the stop event at exit, closes its socket, and waits at most 20 seconds for the polling threads. A Bluetooth read that sees the stop event cancels its current step, disconnects, and returns. A read that waits for the adapter does not connect after a stop.
2026-10-10 11:47:16 +02:00
tim dc1fb95ada Log each failed Bluetooth read with its reason
collect_data printed a failure only with -v, and gave no reason for a failed connection, a failed authentication, or a read with no telemetry. A device that was out of reach showed only as missing data.

Each failed read now gives one log line with the reason, at every debug level. The device object keeps the reason for a failed connection in last_error.
2026-10-10 11:35:43 +02:00
tim 161ae7ee65 Wait for the required EcoFlow reports in each collection
A Bluetooth collection listened for a fixed 10 seconds and returned the data that arrived. If a required report was late, the snapshot missed shared measurements without notice.

Each decoder now tracks the reports behind the shared measurements. A collection listens for 10 seconds, then until those reports arrive, for at most 30 seconds in total. The new ef_missing_measurements field names the reports that did not arrive. The server log shows one line each time that list changes.

The diagnostic tool now uses the River 2 heartbeat list from the decoder.
2026-10-10 09:03:35 +02:00
tim f36bb2510c Rename bms_temperature_celcius to bms_temperature_celsius
Correct the spelling in the JBD and EcoFlow snapshots, the diagnostic tool, and the tests. UPS.from_dict maps the old name to the new name, so a client still reads data from an older server during an upgrade.

InfluxDB and Prometheus now receive this measurement under the new name.
2026-10-10 09:03:33 +02:00
tim 886991caf3 Add River 2 Bluetooth telemetry and diagnostics
Decode River 2 charge, temperature, power flow, and time estimates. Preserve precise charge readings across packet reordering and omit unavailable time estimates.

Require valid PD, EMS, and BMS core heartbeats for diagnostic completion. Report optional packets separately and support raw watch output with reliable disconnect cleanup. Use synthetic regression tests and keep captures, credentials, and external keydata private.

Device details come from command-line arguments or discovery. This commit retains Poetry; the separate packaging commit migrates to uv.
2026-10-08 14:02:45 +02:00