Simplify wording in the documentation
Put each condition before its statement. Split long sentences. Use one term for each concept. Replace the description of possible checklist changes with a statement of the present behavior.
This commit is contained in:
@@ -98,10 +98,10 @@ Empty or truncated reports do not count. Inverter (INV) and solar-controller
|
||||
(MPPT) reports are optional and do not delay completion.
|
||||
|
||||
Raw packet keys include the source module: `ef_pkt_<src>_<cmdset>_<cmdid>`.
|
||||
This keeps reports from different modules separate, even when they share a
|
||||
command number. Watch mode also shows optional reports and unclassified packets.
|
||||
If different modules share a command number, this still keeps their reports
|
||||
separate. Watch mode also shows optional reports and unclassified packets.
|
||||
|
||||
Live R601 checks cover idle, charging, and discharging operation. Automated tests
|
||||
use synthetic packets. These results do not validate River 3 operation.
|
||||
use synthetic packets. These results apply to River 2.
|
||||
|
||||
See the [README](../README.md#ecoflow-bluetooth-le-devices) for setup and commands.
|
||||
|
||||
@@ -36,7 +36,8 @@ Diagnostic collection combines each field's latest value across reports, not one
|
||||
simultaneous measurement. Zero and explicit unavailable values count as received.
|
||||
Malformed messages and required fields with an unexpected encoding do not count.
|
||||
Missing fields do not erase earlier measurements. The normal snapshot omits
|
||||
unusable values even when the diagnostic checklist counts their receipt.
|
||||
unusable values. If the diagnostic checklist counts the receipt of such a value,
|
||||
the snapshot still omits it.
|
||||
|
||||
## Reported fields available to clients
|
||||
|
||||
@@ -51,8 +52,8 @@ InfluxDB and Prometheus export them alongside the normal measurements.
|
||||
Prometheus adds fields that first arrive after the exporter starts.
|
||||
|
||||
Numbers and boolean values use `BMSScalarField.raw_value`.
|
||||
Enum values are named numeric codes. They retain the code in `raw_value` and the
|
||||
name in `value`, when the schema defines a name.
|
||||
Enum values are named numeric codes. They retain the code in `raw_value`.
|
||||
If the schema defines a name, they retain the name in `value`.
|
||||
Only fields with existing unit annotations carry units.
|
||||
Do not assume that an untranslated code or an unannotated number is a physical measurement.
|
||||
|
||||
@@ -131,7 +132,7 @@ still establish that a field arrived.
|
||||
| 254 | `bms_dsg_rem_time` | Battery-management estimate of remaining discharge time, minutes. |
|
||||
| 255 | `bms_chg_rem_time` | Battery-management estimate of remaining charge time, minutes. |
|
||||
| 258 | `bms_min_cell_temp` | Minimum battery-cell temperature, degrees Celsius. |
|
||||
| 259 | `bms_max_cell_temp` | Maximum battery-cell temperature, degrees Celsius. This supplies the normal snapshot temperature when present. |
|
||||
| 259 | `bms_max_cell_temp` | Maximum battery-cell temperature, degrees Celsius. If present, this supplies the normal snapshot temperature. |
|
||||
| 260 | `bms_min_mos_temp` | Minimum temperature at battery switching transistors, degrees Celsius. This is not a cell temperature. |
|
||||
| 261 | `bms_max_mos_temp` | Maximum temperature at battery switching transistors, degrees Celsius. |
|
||||
| 262 | `cms_batt_soc` | Device-level charge estimate, %. This supplies the normal snapshot charge ratio. |
|
||||
@@ -145,8 +146,8 @@ still establish that a field arrived.
|
||||
| 361 | `pow_get_pv` | Solar/DC input power, W. |
|
||||
| 368 | `pow_get_ac_out` | AC output power, W. |
|
||||
|
||||
Individual channel power can be signed even when aggregate output power is
|
||||
positive. Do not apply one sign convention to every power field. The current
|
||||
If aggregate output power is positive, individual channel power can still be
|
||||
signed. Do not apply one sign convention to every power field. The current
|
||||
snapshot uses battery power, not an untranslated state code, to select direction.
|
||||
|
||||
The two time estimates can both be present while only one direction is active.
|
||||
@@ -155,7 +156,7 @@ Their presence does not mean simultaneous charging and discharging. A value of
|
||||
|
||||
## Current configuration checklist: 22 fields
|
||||
|
||||
These values describe settings, limits, and connection state. A configured power
|
||||
These values describe configuration, limits, and connection state. A configured power
|
||||
limit is not a measurement of current power. A charger flag alone does not prove
|
||||
that the battery is receiving power.
|
||||
|
||||
@@ -315,22 +316,13 @@ exit before the third report arrives. If the third report arrives before the
|
||||
next completion check, its fields still appear in the accumulated final view.
|
||||
|
||||
There is no separate, shorter wait period assigned to the second report.
|
||||
Collection checks progress every half second. It stops when the required
|
||||
information is present, rather than when a selected report count or idle period
|
||||
is reached. The watch output does not timestamp each packet, so it cannot
|
||||
Collection checks progress every half second. If the required
|
||||
information is present, it stops. It does not stop at a selected report count or
|
||||
idle period. The watch output does not timestamp each packet, so it cannot
|
||||
establish the exact interval between these reports.
|
||||
|
||||
Adding fields 30, 140, 213, 215, and 232 to a required status group would increase
|
||||
the checklist from 53 to 58 fields. With the observed report layout, collection
|
||||
would then wait for the third report. It would finish on receipt rather than
|
||||
wait until the full timeout. The third report can still take additional time to
|
||||
arrive. No fixed arrival time is established by this capture.
|
||||
|
||||
Requiring those five fields would not guarantee receipt of the other 15 fields
|
||||
on firmware that splits the reports differently. Requiring all 20 would need a
|
||||
broader, firmware-aware policy, especially for reserved and connector fields.
|
||||
Neither change is implemented by this reference. The existing 53-field checklist
|
||||
and verbose missing-field output remain unchanged.
|
||||
The checklist requires 53 fields, and the first two reports supply all of them.
|
||||
With this report layout, use `--watch` to receive the third report.
|
||||
|
||||
## Information that remains unresolved
|
||||
|
||||
@@ -339,7 +331,7 @@ are 17 such messages with seven distinct payloads. Their structure and meaning
|
||||
remain unverified. They must not be assigned field meanings from the protobuf
|
||||
schema merely because some bytes resemble protobuf tags.
|
||||
|
||||
This capture contains no confirmed `0x02/0xFE/0x16` runtime report. It therefore
|
||||
This capture contains no known `0x02/0xFE/0x16` runtime report. It therefore
|
||||
does not establish runtime voltage/current fields from that route. The schema
|
||||
also contains many fields that this device did not report during the capture.
|
||||
|
||||
@@ -369,7 +361,7 @@ and raw bytes, with an error rather than a misleading interpreted value.
|
||||
|
||||
Unknown future field numbers remain numeric/raw. The eight-byte `0x35/0x35/0x20`
|
||||
message is still unclassified. Full schema coverage does not establish the
|
||||
meaning of that separate message or confirm runtime message routing.
|
||||
meaning of that separate message or runtime message routing.
|
||||
|
||||
The descriptor source is upstream commit
|
||||
`511e04702c83ddcc90cdcd575a1bbeffe2f061ad`. Only protocol declarations are retained,
|
||||
|
||||
Reference in New Issue