Fix email, shutdown, and option bugs in bmspy-ups

The recipient check used a regular expression that never matched, so a full address got the host name appended. The main loop passed the device name with a parameter name that read_data does not have. A canceled shutdown did not clear its flag, so a second incident did not schedule a shutdown. The recorded shutdown time used the wrong unit. The --port option stayed text and never matched the STARTTLS ports.
This commit is contained in:
tim
2026-10-10 09:03:34 +02:00
parent 953f8a6482
commit b569bcf27b
2 changed files with 55 additions and 4 deletions
+6 -4
View File
@@ -1,7 +1,6 @@
import argparse
import atexit
import os
import re
import time
import smtplib
import ssl
@@ -65,11 +64,13 @@ def handle_shutdown(action: str = "cancel", delay: int = 0, debug: int = 0) -> N
if action == "shutdown":
if scheduled_shutdown is False:
scheduled_shutdown = time.time() + delay * 60 * 1000
scheduled_shutdown = time.time() + delay * 60
os.system("/sbin/shutdown {}".format(delay))
elif action == "cancel":
os.system("/sbin/shutdown -c")
# Allow the next incident to schedule a shutdown again.
scheduled_shutdown = False
return
@@ -88,7 +89,7 @@ def handle_email(
isSSL = False
hostname = socket.gethostname()
if re.match("/@/", recipient) is None:
if "@" not in recipient:
recipient = "{}@{}".format(recipient, hostname)
sender = "bmspy on {} <nobody@{}>".format(hostname, hostname)
@@ -169,6 +170,7 @@ def main() -> None:
"-p",
dest="port",
action="store",
type=int,
default=25,
help="Mail server port (default: 25)",
)
@@ -229,7 +231,7 @@ def main() -> None:
history = deque()
while True:
data = client.read_data(args.socket, "ups", device=device_name)
data = client.read_data(args.socket, "ups", ups=device_name)
device_obj = data.get(device_name)
if device_obj is None:
time.sleep(DAEMON_UPDATE_PERIOD)
+49
View File
@@ -110,6 +110,16 @@ class TestHandleShutdown:
handle_shutdown(action="cancel")
assert ups_mod.scheduled_shutdown is False
def test_second_incident_after_cancel_schedules_again(self):
with patch("bmspy.ups.os.system") as mock_sys:
handle_shutdown(action="shutdown", delay=5)
handle_shutdown(action="cancel")
assert ups_mod.scheduled_shutdown is False
handle_shutdown(action="shutdown", delay=5)
assert [call.args[0] for call in mock_sys.call_args_list] == [
"/sbin/shutdown 5", "/sbin/shutdown -c", "/sbin/shutdown 5",
]
# ---------------------------------------------------------------------------
# handle_email
@@ -203,6 +213,13 @@ class TestHandleEmail:
args = mock_server.sendmail.call_args[0]
assert args[1] == "root@myhost"
def test_full_address_is_not_changed(self):
mock_smtp_class, mock_server = self._mock_smtp()
with patch("bmspy.ups.smtplib.SMTP", mock_smtp_class), \
patch("bmspy.ups.socket.gethostname", return_value="myhost"):
handle_email(text="test", level="Alert", recipient="user@example.com")
assert mock_server.sendmail.call_args[0][1] == "user@example.com"
# ---------------------------------------------------------------------------
# _resolve_ups_device
@@ -370,6 +387,23 @@ class TestUpsMain:
ups_mod.main()
mock_email.assert_called()
def test_main_mail_port_option_is_a_number(self):
"""A text port never equals 587, so the STARTTLS check would not match."""
ups_mod.warning_sent = False
data_seq = [self._make_data(0.0, 0.60)] * 5
mock_smtp = MagicMock()
server = mock_smtp.return_value.__enter__.return_value
with patch("sys.argv", ["bmspy-ups", "--port", "587"]):
with pytest.raises(StopIteration):
with patch("bmspy.ups.client.read_data", side_effect=[data_seq[0]] + data_seq + [StopIteration("done")]), \
patch("bmspy.ups.client.handle_registration"), \
patch("bmspy.ups.time.sleep"), \
patch("bmspy.ups.handle_shutdown"), \
patch("bmspy.ups.smtplib.SMTP", mock_smtp):
ups_mod.main()
mock_smtp.assert_called_with("localhost", 587)
server.starttls.assert_called()
def test_main_discharge_alert(self):
"""When current goes negative, discharge alert should be sent.
@@ -570,6 +604,21 @@ class TestUpsMainDeviceSelection:
patch("bmspy.ups.handle_email"):
ups_mod.main()
def test_main_loop_calls_read_data_with_its_real_parameters(self):
"""The loop must use the client's parameter names, not only a mock's."""
from unittest.mock import create_autospec
read_data = create_autospec(
ups_mod.client.read_data,
side_effect=[{"testups": _make_ups(0.0, 0.9)}, StopIteration("done")],
)
with patch("sys.argv", ["bmspy-ups", "--socket", "/tmp/test.sock"]), \
patch("bmspy.ups.client.read_data", read_data), \
patch("bmspy.ups.client.handle_registration"):
with pytest.raises(StopIteration):
ups_mod.main()
assert read_data.call_args_list[1] == (("/tmp/test.sock", "ups"), {"ups": "testups"})
def test_main_ups_flag_unknown_device_returns_early(self, capsys):
"""--device with an unknown device name exits with an error."""