Fix email, shutdown, and option bugs in bmspy-ups
The recipient check used a regular expression that never matched, so a full address got the host name appended. The main loop passed the device name with a parameter name that read_data does not have. A canceled shutdown did not clear its flag, so a second incident did not schedule a shutdown. The recorded shutdown time used the wrong unit. The --port option stayed text and never matched the STARTTLS ports.
This commit is contained in:
+6
-4
@@ -1,7 +1,6 @@
|
|||||||
import argparse
|
import argparse
|
||||||
import atexit
|
import atexit
|
||||||
import os
|
import os
|
||||||
import re
|
|
||||||
import time
|
import time
|
||||||
import smtplib
|
import smtplib
|
||||||
import ssl
|
import ssl
|
||||||
@@ -65,11 +64,13 @@ def handle_shutdown(action: str = "cancel", delay: int = 0, debug: int = 0) -> N
|
|||||||
|
|
||||||
if action == "shutdown":
|
if action == "shutdown":
|
||||||
if scheduled_shutdown is False:
|
if scheduled_shutdown is False:
|
||||||
scheduled_shutdown = time.time() + delay * 60 * 1000
|
scheduled_shutdown = time.time() + delay * 60
|
||||||
os.system("/sbin/shutdown {}".format(delay))
|
os.system("/sbin/shutdown {}".format(delay))
|
||||||
|
|
||||||
elif action == "cancel":
|
elif action == "cancel":
|
||||||
os.system("/sbin/shutdown -c")
|
os.system("/sbin/shutdown -c")
|
||||||
|
# Allow the next incident to schedule a shutdown again.
|
||||||
|
scheduled_shutdown = False
|
||||||
|
|
||||||
return
|
return
|
||||||
|
|
||||||
@@ -88,7 +89,7 @@ def handle_email(
|
|||||||
isSSL = False
|
isSSL = False
|
||||||
hostname = socket.gethostname()
|
hostname = socket.gethostname()
|
||||||
|
|
||||||
if re.match("/@/", recipient) is None:
|
if "@" not in recipient:
|
||||||
recipient = "{}@{}".format(recipient, hostname)
|
recipient = "{}@{}".format(recipient, hostname)
|
||||||
sender = "bmspy on {} <nobody@{}>".format(hostname, hostname)
|
sender = "bmspy on {} <nobody@{}>".format(hostname, hostname)
|
||||||
|
|
||||||
@@ -169,6 +170,7 @@ def main() -> None:
|
|||||||
"-p",
|
"-p",
|
||||||
dest="port",
|
dest="port",
|
||||||
action="store",
|
action="store",
|
||||||
|
type=int,
|
||||||
default=25,
|
default=25,
|
||||||
help="Mail server port (default: 25)",
|
help="Mail server port (default: 25)",
|
||||||
)
|
)
|
||||||
@@ -229,7 +231,7 @@ def main() -> None:
|
|||||||
|
|
||||||
history = deque()
|
history = deque()
|
||||||
while True:
|
while True:
|
||||||
data = client.read_data(args.socket, "ups", device=device_name)
|
data = client.read_data(args.socket, "ups", ups=device_name)
|
||||||
device_obj = data.get(device_name)
|
device_obj = data.get(device_name)
|
||||||
if device_obj is None:
|
if device_obj is None:
|
||||||
time.sleep(DAEMON_UPDATE_PERIOD)
|
time.sleep(DAEMON_UPDATE_PERIOD)
|
||||||
|
|||||||
@@ -110,6 +110,16 @@ class TestHandleShutdown:
|
|||||||
handle_shutdown(action="cancel")
|
handle_shutdown(action="cancel")
|
||||||
assert ups_mod.scheduled_shutdown is False
|
assert ups_mod.scheduled_shutdown is False
|
||||||
|
|
||||||
|
def test_second_incident_after_cancel_schedules_again(self):
|
||||||
|
with patch("bmspy.ups.os.system") as mock_sys:
|
||||||
|
handle_shutdown(action="shutdown", delay=5)
|
||||||
|
handle_shutdown(action="cancel")
|
||||||
|
assert ups_mod.scheduled_shutdown is False
|
||||||
|
handle_shutdown(action="shutdown", delay=5)
|
||||||
|
assert [call.args[0] for call in mock_sys.call_args_list] == [
|
||||||
|
"/sbin/shutdown 5", "/sbin/shutdown -c", "/sbin/shutdown 5",
|
||||||
|
]
|
||||||
|
|
||||||
|
|
||||||
# ---------------------------------------------------------------------------
|
# ---------------------------------------------------------------------------
|
||||||
# handle_email
|
# handle_email
|
||||||
@@ -203,6 +213,13 @@ class TestHandleEmail:
|
|||||||
args = mock_server.sendmail.call_args[0]
|
args = mock_server.sendmail.call_args[0]
|
||||||
assert args[1] == "root@myhost"
|
assert args[1] == "root@myhost"
|
||||||
|
|
||||||
|
def test_full_address_is_not_changed(self):
|
||||||
|
mock_smtp_class, mock_server = self._mock_smtp()
|
||||||
|
with patch("bmspy.ups.smtplib.SMTP", mock_smtp_class), \
|
||||||
|
patch("bmspy.ups.socket.gethostname", return_value="myhost"):
|
||||||
|
handle_email(text="test", level="Alert", recipient="user@example.com")
|
||||||
|
assert mock_server.sendmail.call_args[0][1] == "user@example.com"
|
||||||
|
|
||||||
|
|
||||||
# ---------------------------------------------------------------------------
|
# ---------------------------------------------------------------------------
|
||||||
# _resolve_ups_device
|
# _resolve_ups_device
|
||||||
@@ -370,6 +387,23 @@ class TestUpsMain:
|
|||||||
ups_mod.main()
|
ups_mod.main()
|
||||||
mock_email.assert_called()
|
mock_email.assert_called()
|
||||||
|
|
||||||
|
def test_main_mail_port_option_is_a_number(self):
|
||||||
|
"""A text port never equals 587, so the STARTTLS check would not match."""
|
||||||
|
ups_mod.warning_sent = False
|
||||||
|
data_seq = [self._make_data(0.0, 0.60)] * 5
|
||||||
|
mock_smtp = MagicMock()
|
||||||
|
server = mock_smtp.return_value.__enter__.return_value
|
||||||
|
with patch("sys.argv", ["bmspy-ups", "--port", "587"]):
|
||||||
|
with pytest.raises(StopIteration):
|
||||||
|
with patch("bmspy.ups.client.read_data", side_effect=[data_seq[0]] + data_seq + [StopIteration("done")]), \
|
||||||
|
patch("bmspy.ups.client.handle_registration"), \
|
||||||
|
patch("bmspy.ups.time.sleep"), \
|
||||||
|
patch("bmspy.ups.handle_shutdown"), \
|
||||||
|
patch("bmspy.ups.smtplib.SMTP", mock_smtp):
|
||||||
|
ups_mod.main()
|
||||||
|
mock_smtp.assert_called_with("localhost", 587)
|
||||||
|
server.starttls.assert_called()
|
||||||
|
|
||||||
def test_main_discharge_alert(self):
|
def test_main_discharge_alert(self):
|
||||||
"""When current goes negative, discharge alert should be sent.
|
"""When current goes negative, discharge alert should be sent.
|
||||||
|
|
||||||
@@ -570,6 +604,21 @@ class TestUpsMainDeviceSelection:
|
|||||||
patch("bmspy.ups.handle_email"):
|
patch("bmspy.ups.handle_email"):
|
||||||
ups_mod.main()
|
ups_mod.main()
|
||||||
|
|
||||||
|
def test_main_loop_calls_read_data_with_its_real_parameters(self):
|
||||||
|
"""The loop must use the client's parameter names, not only a mock's."""
|
||||||
|
from unittest.mock import create_autospec
|
||||||
|
|
||||||
|
read_data = create_autospec(
|
||||||
|
ups_mod.client.read_data,
|
||||||
|
side_effect=[{"testups": _make_ups(0.0, 0.9)}, StopIteration("done")],
|
||||||
|
)
|
||||||
|
with patch("sys.argv", ["bmspy-ups", "--socket", "/tmp/test.sock"]), \
|
||||||
|
patch("bmspy.ups.client.read_data", read_data), \
|
||||||
|
patch("bmspy.ups.client.handle_registration"):
|
||||||
|
with pytest.raises(StopIteration):
|
||||||
|
ups_mod.main()
|
||||||
|
assert read_data.call_args_list[1] == (("/tmp/test.sock", "ups"), {"ups": "testups"})
|
||||||
|
|
||||||
def test_main_ups_flag_unknown_device_returns_early(self, capsys):
|
def test_main_ups_flag_unknown_device_returns_early(self, capsys):
|
||||||
"""--device with an unknown device name exits with an error."""
|
"""--device with an unknown device name exits with an error."""
|
||||||
with patch("sys.argv", ["bmspy-ups", "--device", "ghost"]), \
|
with patch("sys.argv", ["bmspy-ups", "--device", "ghost"]), \
|
||||||
|
|||||||
Reference in New Issue