Wait for the required EcoFlow reports in each collection

A Bluetooth collection listened for a fixed 10 seconds and returned the data that arrived. If a required report was late, the snapshot missed shared measurements without notice.

Each decoder now tracks the reports behind the shared measurements. A collection listens for 10 seconds, then until those reports arrive, for at most 30 seconds in total. The new ef_missing_measurements field names the reports that did not arrive. The server log shows one line each time that list changes.

The diagnostic tool now uses the River 2 heartbeat list from the decoder.
This commit is contained in:
tim
2026-10-10 09:03:35 +02:00
parent b569bcf27b
commit 161ae7ee65
9 changed files with 249 additions and 11 deletions
+44
View File
@@ -152,6 +152,50 @@ def test_shared_power_and_temperature_measurements_are_floats(decoder_type, pack
assert [type(value) for value in values] == [float, float, float]
def test_river2_collection_is_complete_after_the_three_core_heartbeats():
decoder = ecoflow_river2.River2Decoder()
snapshot = EcoFlowSnapshot()
assert decoder.missing() == {"PD heartbeat", "EMS heartbeat", "BMS heartbeat"}
decoder.update(snapshot, *PD_PACKET)
decoder.update(snapshot, 4, 0x20, 2, bytes(40)) # INV is optional.
decoder.update(snapshot, 3, 0x20, 0x32, bytes(5)) # A short BMS heartbeat is rejected.
assert decoder.missing() == {"EMS heartbeat", "BMS heartbeat"}
# 5999 marks an unavailable estimate. Its heartbeat still counts as received.
decoder.update(snapshot, 3, 0x20, 2, bytes(17) + struct.pack("<II", 5999, 5999))
decoder.update(snapshot, 3, 0x20, 0x32, bytes(20) + b"\x1c")
assert snapshot.ef_charge_remaining_time_minutes is None
assert decoder.missing() == set()
decoder.reset()
assert len(decoder.missing()) == 3
def test_river3_collection_is_complete_across_partial_reports():
def field(number, value):
tag = number << 3 | (5 if isinstance(value, float) else 0)
encoded = bytearray()
for part in (tag, None if isinstance(value, float) else value):
while part is not None:
encoded.append(part & 0x7F | (0x80 if part > 0x7F else 0))
part = part >> 7 or None
return bytes(encoded) + (struct.pack("<f", value) if isinstance(value, float) else b"")
decoder = ecoflow_river3.River3Decoder()
snapshot = EcoFlowSnapshot()
assert len(decoder.missing()) == len(ecoflow_river3.REQUIRED_FIELDS)
first = field(262, 50.0) + field(3, 244.0) + field(4, 39.0) + field(158, -39.0)
decoder.update(snapshot, 2, 0xFE, 0x15, first)
assert decoder.missing() == {
"bms_max_cell_temp or cms_batt_temp", "cms_chg_rem_time", "cms_dsg_rem_time",
}
# Either temperature will do, and an unavailable estimate still counts as received.
second = field(102, 20) + field(268, 0xFFFFFFFF) + field(269, 0xFFFFFFFF)
decoder.update(snapshot, 2, 0xFE, 0x15, second)
assert snapshot.ef_charge_remaining_time_minutes is None
assert decoder.missing() == set()
decoder.reset()
assert len(decoder.missing()) == len(ecoflow_river3.REQUIRED_FIELDS)
def test_snapshot_keeps_diagnostic_packets_and_json_round_trip():